Channel LED - Green Inductive - Loop Traffic Detectors Door Use
Item NO.:Traffic Signal Light Detect System Vehicle Traffic Loop Detector CE Approved
(1) Loop detectors in recent years have become a popular tool having innumerable applications in policing,
right from surveillance operations to traffic control. Automation of gates and doors
has become a popular usage of the loop detector.
(2) The loop consists of several loops of wire and consideration ,should be giving to the loop
sensitivity when installing on different surfaces. Setting the correct sensitivity allows the loop
to operate with maximum detection (8 levels via a trimpot). When detection occurs,
the detector energises 2 relays for the output (each can be configured individually).
This energising of the relay can be configured into different modes, by selecting the respective dip switch.
(3) Fault Output: Blinks slowly: It maybe because the loop is short circuit or the no:of turns is not enough.
Blinks faster: It maybe because the loop is open or the no: of turns is too many.
(4) Modes of operatio
The LD-200 series detector may be configured for any one of the following modes:
Presence Mode
Pulse Mode
AB Logic Presence Mode(Barrier Operation)
AB Logic Pulse Mode(Counting Logic)
Specifications of Dual channel traffic detecting loop detector (LD-200):
ameter for single channel vehicle detector |
Loop Inductance |
20-1500μH |
Response Times |
20MS |
Sensitivity |
8 levels,(0 is lowest, 7 is highest) |
Visual Indications |
Power LED-Red, Channel LED-Green |
ABS |
automatic sensitivity boost |
Direction detection |
CH1 and CH2 flow direction detection |
Loop frequency |
4 setting(low,Med-low,Med-Hi,High) |
Relay signal |
presence signal or pulse signal |
Housing Color |
Green, Black,White/OEM/ODM |
Weight |
0.KG/pc |
Label Language |
English |
Connections |
Socket mount-11pin male(JEDEC B11-88) |
Storage Temperature |
-40 to 80 Celsius degree |
Normal Working Temperature |
-40 to 70 Celsius degree |
Application:
Ordering Information:
LD-200 Dual channel, boxed, 100-240VAC(EU standard)
LD-202 Dual channel, boxed, 12-24VADC(EU standard)
LD-205 Dual channel, boxed, 100-240VAC(USA standard)
LD-206 Dual channel, boxed, 12-24VADC(USA standard)
Troubleshooting:
Symptoms Solution
1. If the detector is nor working--------Press reset
2. If red led indicator is not fully it -----Check for powedr supply
3. If green led indicator : a) Blinks slowly-------It maybe because the loop is short circuit or the no: of turns
is not enough.
b) blinks faster-----It maybe because the loop is open or the no: of turns is too many.
4. If no: of turns is not enough------Lower the frequency (if the frequency is still too high, you must add more turns).
5. If no: of turns is too many----Higher the frequency (if the frequency is still too low, you must remove some turns).
Brochure>>
Software Copyright>>
Certification>>
Compare Video(with Nortech,EMX,Procon,BEA,and China Red loop detector:
https://www.youtube.com/watch?v=LZPIMrxCSbk
https://www.youtube.com/watch?v=0LUQTfA62zs
https://www.youtube.com/watch?v=D5KgiFt4Wtc
https://www.youtube.com/watch?v=HRA0fgTvkc8
https://www.youtube.com/watch?v=Fv1XkRFOSfw
Tag: Vehicle access control, automatic door used ; parking lot sensor system; toll system
Tag : traffic inductive loop, car loop detector
our other loop detector sale;
Parking System Traffic Loop Detector PC Housing 92 * 76 * 42mm
Dual Way Traffic Detection System Gate Loop Detector With Two Relays
12V / 240V Inductive Loop Traffic Detector For Boom Barrier Gate / Door Opener
Black PC Material Inductive Loop Detect Single Channel 0.18kg
Arm Card Readers / Ticket Dispensers PC Ultrasonic Vehicle Detector CE
Shenzhen Noble Opto Co., Ltd.
Contact Person: Ms. Lina Liao
Tel:86-755-2765-1481
Fax:86-755-2765-1483
|