Black PC Material Inductive Loop Detect Single Channel 0.18kg
USA market use traffic loop detector Black color 0.18kgTraffic Loop Detectors in recent years have become a popular tool having innumerable applications in policing, right from surveillance operations to traffic control. Automation of gates and doors has become a popular usage of the loop detector. |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Self-turning range | 20-2000μH |
| Response Times | 10-90MS |
| Sensitivity | 16 way selectable levels |
| Visual Indications | Power LED-Red, Channel LED-Green |
| Frequency | Four step switch, selectable 20-80KHz |
| Relay Output | Presence Relay/Fault Relay |
| Power Requirements | 110-240VAC (48 to 62Hz) |
| Fault Output | Blinks slowly, Blinks faster |
| Reset | Reset by push button on front of enclosure |
| Product size | 92*76*42mm |
| Label Language | English |
| Connections | 11-pin Submagnal |
| Storage Temperature | -40 to 80 Celsius degree |
| Normal Working Temperature | -40 to 70 Celsius degree |
Loop Installation:
The loops are sealed using a “quick-set” black epoxy compound or hot bitumen mastic to blend with the
roadway surface.
| Loop perimeter | Cylinder numbers |
| 3 ~ 4 M |
6 |
| 4 ~ 6 M | 5 |
6 ~ 10 M |
4 |
| 10 ~ 20 M | 3 |
20 M~ UP |
2 |
Competitive Advantage:
Self-turning range: 20-2000μH
Response Times: Turn-on 10-90MS
Turn-off 10-90MS
Sensitivity: 16 way selectable
Highest 0.010% DL/L
Lowest 2.56% DL/L
Applications:
Troubleshooting:
| Symptoms | Solution |
|
| If the detector is not working? |
Press reset |
|
| If red led indicator is not fully lit? | Check for power supply | |
If green led indicator ? |
Blinks slowly? | It maybe because the loop is short circuit or the no: of turns is not enough |
| Blinks faster? | It maybe because the loop is open or the no: of turns is too many. | |
If no: of turns is not enough? |
Lower the frequency (if the frequency is still too high, you must add more turns). | |
| If no: of turns is too many? | Higher the frequency (if the frequency is still too low, you must remove some turns). | |
Loop detector order information:
LD-100 single channel, boxed, 1 type 11pin connects 100-240VAC
LD-102 single channel, boxed, 1 type 11pin connects 12-24VADC
LD-105 single channel, boxed, 2 type 11pin connects 100-240VAC
LD-106 single channel, boxed, 2 type 11pin connects 12-24VADC
Brochure>>
Tag :
our other loop detector sale;
12V / 240V Inductive Loop Traffic Detector For Boom Barrier Gate / Door Opener
Black Traffic Light Sensors For Access Control System / Car Parking Management
Dual Way Traffic Detection System Gate Loop Detector With Two Relays
12V / 240V Double Way Traffic Loop Detector With Traffic Directional Detection Fuction
Parking System Traffic Loop Detector PC Housing 92 * 76 * 42mm