Building 1-2F, Mingjinhai Industry
Park,
Tangtou Road,Shiyan Town, Bao'an District
Shenzhen, China.518108
WeChat:598734944 or 992452228
Tel : (86 755) 2765 1481
Fax : (86 755) 2765 1483
E-mail : sales@nobleled.com
Send message to us
AC110v Intelligent 8 Levels Sensitivity Vehicle Loop Detector For Toll Station
Detailed Product Description
Specifications :
Description: (1) Loop detectors in recent years have become a popular tool having innumerable applications in policing, right from surveillance operations to traffic control. Automation of gates and doors has become a popular usage of the loop detector. (2) The loop consists of several loops of wire and consideration ,should be giving to the loop sensitivity when installing on different surfaces. Setting the correct sensitivity allows the loop to operate with maximum detection (8 levels via a trimpot). When detection occurs, the detector energises 2 relays for the output (each can be configured individually). This energising of the relay can be configured into different modes, by selecting the respective dip switch. (3) Fault Output: Blinks slowly: It maybe because the loop is short circuit or the no:of turns is not enough. (4) Modes of operation: The LD-200 series detector may be configured for any one of the following modes: Presence Mode Pulse Mode AB Logic Presence Mode(Barrier Operation) AB Logic Pulse Mode(Counting Logic) Troubleshooting: Symptoms Solution
1. If the detector is nor working--------Press reset 2. If red led indicator is not fully it -----Check for powedr supply 3. If green led indicator : a) Blinks slowly-------It maybe because the loop is short circuit or the no: of turns is not enough. b) blinks faster-----It maybe because the loop is open or the no: of turns is too many. 4. If no: of turns is not enough------Lower the frequency (if the frequency is still too high, you must add more turns). 5. If no: of turns is too many----Higher the frequency (if the frequency is still too low, you must remove some turns) Competitive Advantage: Self-turning range: 20-2000μH Response Times: Turn-on 10-90MS Turn-off 10-90MS Sensitivity: 16 way selectable Highest 0.010% DL/L Lowest 2.56% DL/L LD-200 Connections:
Ordering Information: LD-200 single channel, boxed, 1 type 11pin connects 100-240VAC(EU standard) LD-202 single channel, boxed, 1 type 11pin connects 12-24VADC(EU standard) LD-205 single channel, boxed, 2 type 11pin connects 100-240VAC(USA standard) LD-206 single channel, boxed, 2 type 11pin connects 12-24VADC(USA standard) Application: Brochure>> Tag : traffic light detector, inductive loop traffic detector
our other loop detector sale;
|