ABS intelligent Traffic Loop Detector for Gate Closing , Traffic Detection Systems
Model Number: |
LD-100-24VADC |
Place of Origin: |
Shenzhen,China |
Brand Name: |
Noble |
Certification: |
Patent,ISO9001-2008,CE,FCC |
Minimum Order Quantity: |
5PCS |
Price: |
USD50-100/pc |
Packaging Details: |
cartons |
Delivery Time: |
5-8days |
Payment Terms: |
Western Union, T/T |
Supply Ability: |
20000pcs per months |
Detailed Product Description
Self-turning Range: |
20-2000uh |
Response Times: |
10-90MS |
Sensitivity: |
0-15 Levels(0 Is Low,15 Is High) |
Operation Temp: |
-40℃ To +70℃ |
Work Voltage: |
24VADC |
Connection: |
USA Style And European Style |
Visual Indications: |
Power LED-Red,Fault LED-Green |
Housing Color: |
Black Or White |
Output Signal: |
Presence Signal And Pulse Signal |
Relay Output: |
Enable |
ABS intelligent Traffic Loop Detector for Gate Closing , Traffic Detection
Systems
Description:
The NBT-ILD™ vehicle loop detector is compatible with most gate operators.
The ULT-MVP may be used in Center, Safety and Exit loop positions.Fifteen
sensitivity settings allow for fine adjustment of the detection level.
The loop consists of several loops of wire and consideration should be giving
to the loop sensitivity when installing on different surfaces. Setting the correct
sensitivity allows the loop to operate with maximum detection (16 levels via
a trimpot). When detection occurs, the detector energises 2 relays for the
output (each can be configured individually). This energising of the relay can be configured into different modes, by selecting the respective dip switch.
Loop detectors in recent years have become a popular tool having innumerable applications in policing, right from surveillance operations to traffic control.
Automation of gates and doors has become a popular usage of the loop
detector.
Sensitivity Selection
Sensitivity of the loop can be adjusted by the trimpot labeled “Sensitivity”.
User can select 16 different setting by turning the trimpot with 0 being the least
sensitive and “F” being the most sensitive.
Power Led: RED power LED indicates “Power ON”
Detecting Led: Continuously On: Indicates vehicle detection.
Blinking slowly: Indicates loop is short circuit or the number of twists after the
loop is not enough.
Blinking fast: Indicates loop is open circuit or too many twists after the loop.
Features:
Two separate output relays:
Presence Relay A is presence output. Can be extended for 0,2,5,8,10,15,20 or 30
seconds, programmable with external 10 way DIP switches.
Pulse Relay B, programmable with external 10 way DIP switches, provides presence,
pulse on entry, pulse on exit, or failed output.
Selectable Presence Time: The output of the presence Relay can be selected to limit
a detect output to a fixed time(time>30 minutes)while a vehicle remains on the loop
Loop Frequency Indication: Interference between adjacent loop/detectors can be
determined by an integral indication, and eliminated by changing the frequency setting.
Technical Parameter for single channel vehicle detector |
Self-turning range |
20-2000μH |
Response Times |
10-90MS |
Sensitivity |
0-F(0 is Low - F is High) |
Visual Indications |
Power LED-Red, Channel LED-Green |
ABS |
automatic sensitivity boost |
Relay time |
0,2,4,8,10,15,20,30 seconds |
Power Requirements |
12-24VADC,110-240VAC |
relay signal |
presence signal and pulse signal |
Presence time |
NORMAL/INFINITE |
Product size |
92*76*42mm |
Label Language |
English |
Connections |
11-pin Submagnal(USA style and European) |
Storage Temperature |
-40 to 80 Celsius degree |
Normal Working Temperature |
-40 to 70 Celsius degree |
For USA connection:
Pin |
LD-105 |
LD-106 |
1 |
100-240V AC |
12-24VADC |
2 |
100-240V AC |
12-24VADC |
3 |
Pulse B Relay N.O |
4 |
Chassis Ground |
5 |
Presence A Relay COM |
6 |
Presence A Relay N.O |
7 |
Loop |
8 |
Loop |
9 |
Pulse B Relay COM |
10 |
Presence A Relay N.C |
11 |
Pulse B Relay N.C |
Troubleshooting:
Symptoms |
Solution |
If the detector is not working |
Press reset |
If red led indicator is not fully lit |
Check for power supply |
If green led
indicator:
|
Blinks slowly |
It maybe because the loop is short circuit or the no: of turns is not enough. |
Blinks faster |
It maybe because the loop is open or the no: of turns is too many. |
If no: of turns is not enough |
Lower the frequency (if the frequency is still too high, you must add more turns). |
If no: of turns is too many |
Higher the frequency (if the frequency is still too low, you must remove some turns). |
Application:
Traffic Control Application
parking Vehicle Counting
parking control management system
autogate control
barrier control
Parking system use vehicle detector control:
Tag:traffic loop detector,vehicle loop detector.
Ordering Information:
LD-100 single channel, boxed, 1 type 11pin connects 100-240VAC(EU standard)
LD-102 single channel, boxed, 1 type 11pin connects 12-24VADC(EU standard)
LD-105 single channel, boxed, 2 type 11pin connects 100-240VAC(USA standard)
LD-106 single channel, boxed, 2 type 11pin connects 12-24VADC(USA standard)
Brochure>>
Software Copyright>>
Certification>>
Compare Video(with Nortech,EMX,Procon,BEA,and China Red loop detector:
https://www.youtube.com/watch?v=LZPIMrxCSbk
https://www.youtube.com/watch?v=0LUQTfA62zs
https://www.youtube.com/watch?v=D5KgiFt4Wtc
https://www.youtube.com/watch?v=HRA0fgTvkc8
https://www.youtube.com/watch?v=Fv1XkRFOSfw
Tag :
traffic light detector, inductive loop traffic detector
our other loop detector sale;
White Door Inductive Loop Vehicle Detector 12VDC / 110VAC ISO9001-2008 High Speed Traffic Loop Detector 20uh - 2000uh with Barrier Closing
Single Channel Loop Detector Traffic Barrier Gate 11-Pin Submagnal
Monthly Supply 50000 Pieces 0.18 Kg Traffic Loop Detector For Parking System
|